| Engineered to give you more of everything you need for routine burner and boiler maintenance, etc. |
| Engineered to give you more of everything you need for routine burner and boiler maintenance, tuning, O2, CO2, CO and combustion efficiency checks. These units offer a sleek design and superior performance capabilities at breakthrough prices. |
| |
|
Features |
- Backlit display
- Differential Pressure/Draft Testing
- CO measurements up to 4,000 ppm
- Immediate print out of readings on-site, with date and time and instrument serial number using wireless, infrared printer
- New and improved carry case
- Hands free operation with convenient magnetic backed, protective, SoftCase
- Stores and prints separate Ambient CO reading
- Four fuel choices: Natural gas, Propane, Light Oil, Heavy Oil
|
| | | SPECIFICATIONS
| Temperature Measurement |
| Measurement Range |
-40 to +1112 °F |
| Accuracy |
± 1 °F |
| Resolution |
0.1 °F |
| Sensor |
Thermocouple type K (NiCr-Ni) |
| Draft/Pressure Measurement |
| Measurement Range: |
± 16" H2O and ± 80" H2O |
| Accuracy |
0.01" H2O |
| Resolution |
0.01" H2O |
| Net Efficiency |
| Measurement Range |
0 to 100% |
| Resolution |
0.1% |
| O2 Measurement |
| Measurement Range |
0 to 21% by volume |
| Accuracy |
0.2% vol. absolute |
| Resolution |
0.1% vol |
| Response time |
T90 = < 45 seconds |
| CO2 Calculation |
| Display Range |
0 to CO2 max |
| Accuracy |
0.2% vol. |
| Resolution |
0.1% vol |
| Measurement |
Digital calculation from O2 |
| CO Measurement: |
| Display Range |
0 to 4,000 ppm |
| Accuracy |
± 5% of reading |
| Resolution |
1 ppm |
| Response time |
T90 = < 45 seconds |
| Power Supply |
Optional 70 VAC source or Battery: 4 AA |
| Dimensions |
8.5 x 3 x 2 inches |
| Weight |
Approximately 16 oz |
| Warranty |
2 years |
| Operating Temperature |
40 to 113 °F |
| Storage Temperature |
-5 to 122 °F |
| TT32515/6 |
| Stores |
20 records with date and time |
| 6 fuel choices |
including Coal and kerosene |
Recall stored records to display or print Recharge include NiCad batteries in the analyzer |
| CAT NO. |
 |
MODEL |
 |
DEscRIPTION |
 |
AVAIL |
 |
PRICE |
| TT32511 |
|
325M1 |
|
Analyzer, probe, vinyl case |
|
Yes |
|
1,509,840 |
| TT32513 |
|
325M3 |
|
Analyzer, soft case, probe, carry case, includes IR printer |
|
Yes |
|
2,157,840 |
| TT32514 |
|
325M4 |
|
Analyzer, soft case, probe, carry case, includes IR printer and smoke tester |
|
Yes |
|
2,589,840
|
| TT32515 |
|
325XL |
|
Datalogging Analyzer, soft case, probe, carry case with NiCad batteries and power supply |
|
Yes |
|
2,797,200
|
| TT32516 |
|
325XLP |
|
Datalogging Analyzer, soft case, probe, carry case featuring 16 foot sampling house with NiCad batteries and power supply |
|
Yes |
|
3,531,600
| | |
|
|
 | |
 |
|
 |
|
이 상품에 대한 사용후기가 아직 없습니다.
사용후기를 작성해 주시면 다른 분들께 많은 도움이 됩니다. |
|
 |
|
 |
|
|
 | |
 |
|
 |
|
이 상품에 대한 질문이 아직 없습니다.
궁금하신 사항은 이곳에 질문하여 주십시오. |
|
 |
|
 |
|
|
|