| Dewpoint Meter. Sensor Storage - When not in use the sensor is retracted in a molecular sieve container. |
|
Features
|
- Sensor
Storage - When not in use the sensor is retracted in a
molecular sieve container. The sample gas pressure activates
a piston which automatically moves the sensor into the
sampling chamber.
- Indicators
- LCD with backlight, 3.5 digits and custom legends for
units and mode, audio alert
- Engineering
Units - °C, °F, PPM, lbs. H2O/mm scf, gm. H2O/m3
- Controls
- 5 push buttons, all settings stored in EEprom. Manual
Sensor Actuator
- Output
- Optional 4/20 mA or 0/24 mA and RS-232
- Isolation
- Sensor and case are isolated from the power supply, analog
output and RS-232
- Battery
saver - Auto power off after 6 minutes
- Pressure
Correct - Programmable pressure correction button
- Input
Resolution - 0.1°C dewpoint
|
| |
|
SPECIFICATIONS
|
Type
|
Hyper Thin Film
high capacitance AL203 |
| Dewpoint range |
-148°F to +68°F
(-100°C to +20°C) |
| Accuracy |
±5.5°F (±3°C) |
| Repeatability |
±0.9°F (±3°C) |
| Response time |
For a step change
from -40°C to -60°C; 63% in 90 seconds; 90% in 450 seconds |
| Temperature
range |
| |
Sensor: -22°F to
120°F (-30°C to +50°C) |
| |
Electronics: 14°F
to +120°F (-10°C to +50°C) |
| Storage temperature |
-4°F to +140°F
(-20°C to +60°C) |
| Sample flow range |
Static to 100 m/s
(linear velocity @ 1 atm) |
| Calibration method |
Automatic
calibration, sensor saturates at dew points above +68°F (+20°C). NIST
traceable factory calibration optionally available |
| Temperature
and pressure measurements |
| The
sample temperature is measured with a precision integrated circuit
temperature sensor. Units may be optionally fitted with a pressure
sensor |
| Mechanical |
| Enclosure |
Anodized aluminum |
| Dimensions |
2.5" x
4.25" x 7.5" |
| Regulator
and filter mounting facilities |
| Sampling chamber |
Electro-polished
316 stainless steel |
| Moving parts seals |
Spring energized
PTFE seals |
| Pressure
operating range |
Standard: 28 PSI (2
bar) |
| Absolute max: 100
PSI (6.9 bar) |
| Gas sample
connections |
1/4" VCO input
and output ports |
| Power requirements |
9V battery and
optional 15-25 V AC or DC wall transformer |
| CAT
NO. |
 |
MODEL |
 |
DEscRIPTION |
 |
AVAIL |
 |
PRICE |
| CS71110 |
|
XR7170 |
|
PORTABLE
DEWPOINT MTR. 100/+20°C |
|
Yes |
|
9,933,840
|
| CS10024 |
|
XR10024 |
|
OPTIONAL
CARRYING CASE FOR
High Speed Portable Dewpoint Meter |
|
Yes |
|
486,000
|
| |
|
|
 | |
 |
|
 |
|