ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > ¿Âµµ Temperature > ¿Âµµ½ë¼­ Probes
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
IP500 Fiber optic temperature monitoring system
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Fiberoptic temperature sensors offer reliability and accuracy
LumiTherm¢â fiberoptic thermometers provide accu-rate and reliable measurements where others can't. The units can be used in high electromagnetic interference (EMI) environments, especially suitable for monitoring high voltage transformers and microwave processes. Fiber optic cladding makes the probes inert and safe to use in harsh chemical environments such as refineries, chemistry labs, mining operations, and pharmaceutical manufacturing. Probes are autoclaveable and instru-ment is self-calibrating. The LumiTherm¢â 500 is fully calibrated at the factory to NIST traceable standards. Calibration data for each probe is stored in individual Calibration Data Modules that are shipped with the probe. High stability, minimum drift.

Benefits
- High repeatability and accuracy of data - Expedites time spent from analysis to discovery of results - Saves time during processing and allows investigator to change conditions if needed - Flexibility in use of unit for many appli-cations - Ideal for microwave/RF or MRI envi-ronments - Probes can be reused saving future expenditures

 
Pharmaceutical & Biomedical
  • Real Time data logging & sample prep monitoring
  • Pharmacokinetic studies
  • Cardiac studies monitoring plaque inflammation
  • Map margins of metastasis of tumors
 
RF and Microwave Processing/ MRI
  • FMRI studies and cryogenic or laser prostate
  • Drying of pharmaceuticals and waste slurries
  • Curing of composites, resins and petroleum
  • Food processing, packaging and testing
  • Monitoring e-fields during processing
 
High Spark Hazard Processes
  • Operational maintenance of hydro-generators
  • Battery manufacturing and testing
  • Propellant extrusion and packaging
  • Chemical/Petroleum processing
  • Corrosive/electrochemical production control
  • Nuclear power plant monitoring
 
Electrical Power Generation
  • Hot spot monitoring in generators and transformers
  • Monitoring of winding temperatures
  • Diagnostic testing of high voltage components
 
SPECIFICATIONS — IP500

Range

-50 to 400 ¡ÆC (-58 to 752 ¡ÆF)
Accuracy ¡¾ 0.1 ¡ÆC
Repeatability ¡¾ 0.2 ¡ÆC
Precision Up to 0.01 ¡ÆC
NIST Traceable Absolute accuracy ¡¾ 1.0 ¡ÆC
Method Fluordecay

SPECIFICATIONS — IP104

Range

-20 to 80 ¡ÆC (-5 to 175 ¡ÆF)
Accuracy ¡¾0.1 ¡ÆC
Precision 0.01 ¡ÆC (FAST mode)
0.001 ¡ÆC (HI-RES mode)
NIST Traceable Absolute accuracy ¡¾1.0 ¡ÆC
Method Quartz Oscillator
Applications Calorimetry and phase change assays

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
IP500   LumiTherm¢â 500   LumiTherm¢â 500 Turn-Key Package   Yes   9,180,000
Fiber optic temperature monitoring system. LED display, RS232 port, analog output and alarms, two standard autoclaveable Teflon probes, one fiber optic probe holder, VI interface driver (for LabView software only), LT 500 users manual. Reads temperature -50-400 ¡ÆC, programmable unit with alarms for max. and min. temp., portable carrying case and Windows laptop included. 
IP501   ¡¡ ¡¡ LT500 autoclaveable standard Teflon Probe   Yes   642,600
IP502   ¡¡ ¡¡ LT500 hybrid e-field/ temperature probe   Yes   807,840
IP503   ¡¡ ¡¡ LT500 high temperature ceramic sheath probe   Yes   1,193,400
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ