ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > ±³Á¤±â Calibrators > ¾Ð·Â Pressure

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
BE325 Beta Intrinsically Safe Pressure Calibrator
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:BE325
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
This unit is both a two-channel and multi-range device.23 Interchangeable pressure modules
This unit is both a two-channel and multi-range device. Changing ranges is as easy as plugging in new input modules, which can be done even while the unit is powered up. The signals from installed modules are automatically recognized and assigned to the proper channel. External pressure connection is made by a 1/8" FNPT 316SS connector. This plug-in design also simplifies maintenance. Only the input modules themselves require re-calibration. You send only the out-of-calibration modules back to the shop, while still using the unit in the field.

When operated in the documenting mode, the unit works with many popular calibrating software packages including Emerson AMS, Cornerstone, and Honeywell Document. Instrument tag numbers and calibration routines can be downloaded and used for field calibration. When tests are completed, the data can be uploaded back into the host calibration software.
 
Features
  • Intrinsically safe design for use in Class I Div 2, Groups A, B, C & D hardous areas
  • 14 selectable engineering units; kg/cm2; ATM; mBAR; BAR; kPa; mmHg; ¡°Hg; ¡°H20 at 4¡ÆC, 20¡ÆC, 60¡ÆF; cmH2O at 4¡ÆC, 20¡ÆC, 60¡ÆF
  • Accuracy: pressure ¡¾0.025% FS, Electrical ¡¾0.01% FS
  • 23 Interchangeable pressure modules
  • Minimum/maximum measurement memory
 
SPECIFICATIONS

DC input module

  Accuracy ¡¾0.01% FS ¡¾0.01% rdg
  Ranges 0 to ¡¾249.99 mVDC; 0 to ¡¾2.4999 and ¡¾24.999 VDC; 0 to 24.999
    and 149.99 mADC
Environmental
Temperature/humidity -20¡ÆC to 50¡ÆC (operating) / 0 to 95%
Alarm trip detect Wet contact input, 48 VDC max.
Power supply Rechargeable NiCd external battery pack
Charging 16 hours maximum; fast charge battery optional, 90 min. charge time
Size/weight 4.3" x 7.5" x 2.4" (70mm x 190mm x 60mm)/ 1.5 kg with carrying case and accessories

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
BE325   910325-70   Beta Intrinsically Safe Pressure Calibrator   Yes   2,797,200
Iincludes: Voltage/current input module, rechargeable NiCd, one set of test leads, trickle charger, instruction manual, vinyl carrying case, 9-pin D shell to 9-pin D shell serial cable.
BE3251   325K   Beta Kit – includes Gauge and one pressure module (please specify pressure range)   Yes   3,877,200 
Iincludes: Voltage/current input module, rechargeable NiCd, one set of test leads, trickle charger, instruction manual, vinyl carrying case, 9-pin D shell to 9-pin D shell serial cable.
BE3252   917007-001   Spare DC Input Module   Yes   1,285,200
BE3700   917004-001   Spare Intrinsically Safe Battery Pack   Yes   507,600
BE910331-005   910331-005   OPTIONAL Module, 0 to 5 PSIG (0 to 350 mBAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200
BE910331-007   910331-007   OPTIONAL Module, 0 to 7.2 PSIG (0 to 500 mBAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200
BE910331-010   910331-010   OPTIONAL Module, 0 to 10 PSIG (0 to 700 mBAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200
BE910331-030   910331-030   OPTIONAL Module, 0 to 30 PSIG (0 to 2 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910331-050   910331-050   OPTIONAL Module, 0 to 50 PSIG (0 to 3.5 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910331-100   910331-100   OPTIONAL Module, 0 to 100 PSIG (0 to 7 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910331-150   910331-150   OPTIONAL Module, 0 to 150 PSIG (0 to 10 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910326-300   910326-300   OPTIONAL Module, 0 to 300 PSIG (0 to 20 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200 
BE910326-301   910326-301   OPTIONAL Module, 0 to 1,000 PSIG (0 to 70 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910326-315   910326-315   OPTIONAL Module, 0 to 1,500 PSIG (0 to 100 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910326-303   910326-303   OPTIONAL Module, 0 to 3,000 PSIG (0 to 200 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910326-305   910326-305   OPTIONAL Module, 0 to 5,000 PSIG (0 to 350 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910329-005   910329-005   OPTIONAL Module, 0 to 5 PSID (0 to 350 mBAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910329-030   910329-030   OPTIONAL Module, 0 to 30 PSID (0 to 2 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910329-050   910329-050   OPTIONAL Module, 0 to 50 PSID (0 to 3.5 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910327-005   910327-005   OPTIONAL Module, 0 to -5 PSIG (0 to -350 mBAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910327-015   910327-015   OPTIONAL Module, 0 to 7-15 PSIG (0 to -1 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910332-015   910332-015   OPTIONAL Module, 0 to 15 PSIA (0 to 1 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910332-030   910332-030   OPTIONAL Module, 0 to 30 PSIA (0 to 2 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910332-050   910332-050   OPTIONAL Module, 0 to 30 PSIA (0 to 2 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910332-100   910332-100   OPTIONAL Module, 0 to 100 PSIA (0 to 7 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910333-015   910333-015   OPTIONAL Module, -15 to 15 PSG (-1 to 1 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

BE910333-030   910333-030   OPTIONAL Module, -15 to 30 PSG (-1 to 2 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator   Yes   1,501,200

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ