NANOVIP CUBE NANOVIP TWO

PORTABLE POWER ANALYSERS

DEscRIPTION


POWER AND HARMONICS ANALYSER

NANOVIP/CUBE FOR SINGLE PHASE AND UNBALANCED THREE PHASE SYSTEMS

NANOVIP/TWO FOR SINGLE PHASE AND BALANCED THREE PHASE SYSTEMS  


IMPLEMENTATION OF FIRMWARE AND SOFTWARE FOR RECOGNITION OF CT CLAMPS

For information visit NEW AREA or send an email to sales@elcontrol-energy.net or call the phone number +39 051 678 2006


NANOVIP/CUBE and NANOVIP/TWO can measure more than 600 parameters and show them in a big high contrast LCD display.

Both products measure the Harmonics up to the 50th component, and DC current (with a special CT clamp).

The USB port and the dedicated software called NANOSTUDIO assure the complete visualization of the graphics and the deep analysis of the data, when downloading a survey. Data will be transferred from a 2GB microSD to the hard disk of your PC.

High portability, excellent performances, and the best price/performance ratio in the market: NANOVIP/CUBE and NANOVIP/TWO should be included in all technicians� toolkits.

REAL TIME MEASURES

Real time measures of: Volt, Ampere, Watt, VAr, VA, PF, Hz, kWh, kvarh (inductive/capacitive), instant values /min/max/average, energy counters of the energy consumed and generated in the whole three phase system and on each line.
The measures are in RMS, precision class is 0.5.
Both NANOVIP/CUBE and NANOVIP/TWO can measure DC current (by using special Hall뭩 effect CT clamps).
Automatic set-up of the connected CT clamp: it is no more required the manual set-up to the user. 

 


QUALITY OF THE ENERGY ANALYSIS


뷖urrent and tension Harmonics measured on each phase and on the neutral wire.
뷫nbalance of the tensions of three phase systems.
뷥ower supply interruption and high peak tension.

뷖onformity test to the EN 50160.



SPECIAL FUNCTIONS

뷧eal measure of the neutral current.
Visualization of the wave forms of the currents and the tensions.
�4 band tariff and display of the related costs.
뷖onfiguration and display of alarms.
뷪rend display.
뷖heck of the correct connection of the instrument to the phases.
뷬ery Long time surveys.
뷡anguages that can be set:  Italian, English, Spanish, German and French.
뷗isplay that can be customized, by choosing the measures to display rotating in the bottom line.

 

 

TECHNICAL SPECIFICATION


� Power Supply:  4 batteries AA NiMh 2100mAh

� Battery duration: >24  hours  
 
� Voltage inputs (CUBE: 3 channels + 1 Aux; TWO: 1):  Phase - phase: 1000Volt AC  Phase - neutral: 600Volt

� Input voltage Impedance:  4MOhm
   
� Current (CUBE: 5 channels; TWO: 1 channel): Maximum displayed value: 500 kA 

� Input current Impedance: 10kOhm

� Display:  LCD 68x68mm

� Precision: Class 0.5  (EN 62053-21)

� Voltage input overload:  Max  1200Volt phase-phase - 700Volt phase-neutral

� Total scales: 2 voltage scales, 4 current scales

� Scale change: Automatic

� Memory:  2GB microSD

� Instrument Dimensions :   203x116x53 mm

� Instrument Weight: 580 g 

� Protection degree: IP30

� Operating Temperature Range: -10캜 +55캜

� Storage Temperature Range: -20캜 +85캜

� Relative Humidity Range (RH%): 20% - 95%

� Condensation: not allowed


PRIMARY MEASUREMENT ACCURACY

� Measure method: 128 samples/period and analogic/digital conversion.

� Sampling frequency: 6400 cycles/second at 50 Hz (7680 cycles/second at 60 Hz).

� Number of samples: 128 each period.

STANDARD AND REGULATIONS

NANOVIP/CUBE and NANOVIP/TWO conform to directive 93/68/CEE (LVD), 89/336/CEE, 2004/108/CE (EMC), 2002/95/CE (RoHS), 2006/95/CE � 72/23/CEE, 2002/96/CE and successive modifications 2003/108/CE; EN 55022: 1998 (Class A); EN 61000 -3-3: 1995+A1: 2001; EN 55024: 1998 + A1: 2001. E and conform to the norms EN 61010-1, EN 61326 including addendums  A1/A2/A3, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-6, IEC 60068-2-30, IEC 60947-1.

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óǰÀ» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óǰ¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§
°æ±âµµ ¼º³²½Ã Áß¿ø±¸ »ó´ë¿øµ¿ 513-15¹øÁö ¼±ÅØ½ÃÆ¼B/D 708È£
´ëÇ¥ ÀüÈ­ : 031-777-1588 / ÆÑ½º : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆÇ¸Å¾÷½Å°í ¼º³²½Ã Á¦2005-886È£
´ëÇ¥ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
Copyright ¨Ï 2002 »óÈ£ : (ÁÖ)ÄÚ¸°½º. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ